The Nanoscale World

Browse Site by Tags

Showing related tags and posts across the entire site.
  • Re: Celgard Fans: Fresh FastScan Video –or- Another High-Speed AFM benchmark sample?

    PS: A good test of the robustness of a system is to scan Celgard® in different orientations; here is an even faster video (23Hz) where the mesh is perpendicular to the scan. Enjoy, Steve
    Posted to SPM Digest by Stephen Minne on Sun, Jun 12 2011
  • Celgard(R), 1um, 23Hz, Perpendicular Mesh Orientation

    It’s good to see some community attempts at replicating the performance of the Dimension FastScan. The video is of a 1um, 512x512, 23Hz, scan of Celgard® taken with the Dimension FastScan. This demonstration is over twice as fast as the 10Hz video we showed previously, additionally we demonstrate...
    Posted to Webinars and Video by Stephen Minne on Sun, Jun 12 2011
    Filed under: TappingMode, FastScan, Celgard
  • FastScan AFM is Productivity

    I was reading an AFM site and saw a contrived claim trying to make a comparison that was >50% off the benchmark and thought it would be a good topic to open up for discussion. The comment was to the effect of: by scanning at a slower scan speed we are actually going faster because our poor scanner...
    Posted to SPM Digest by Stephen Minne on Sat, Jun 11 2011
  • Dimension FastScan Productivity Grand Challenge

    I was reading an AFM site and saw a contrived claim trying to make a comparison that was over 50% off the benchmark and thought it would be a good topic to open up for discussion. The comment was to the effect of: by scanning at a slower scan speed we are actually going faster because our poor scanner...
    Posted to Webinars and Video by Stephen Minne on Sat, Jun 11 2011
    Filed under: TappingMode, FastScan, Celgard, C60H122, SBS
  • Re: Celgard Fans: Fresh FastScan Video –or- Another High-Speed AFM benchmark sample?

    It’s good to see some community attempts at replicating the performance of the Dimension FastScan. The screen shot below is of a 1um, 512x512, 22Hz, Video of Celgard® taken with the Dimension FastScan (Video link at end). This demonstration is over twice as fast as the 10Hz video we show above...
    Posted to SPM Digest by Stephen Minne on Sat, Jun 11 2011
  • Celgard(R) Imaged at 44um/s (22Hz) with Dimension FastScan

    It’s good to see some community attempts at replicating the performance of the Dimension FastScan. The screen shot below is of a 1um, 512x512, 22Hz, Video of Celgard® taken with the Dimension FastScan (Video link at end). This demonstration is over twice as fast as the 10Hz video we show above...
    Posted to Webinars and Video by Stephen Minne on Sat, Jun 11 2011
    Filed under: TappingMode, FastScan, Celgard
  • Dimension FastScan 22Hz Celgard(R) Image

    It’s good to see some community attempts at replicating the performance of the Dimension FastScan. The screen shot below is of a 1um, 512x512, 22Hz, Video of Celgard® taken with the Dimension FastScan (Video link at end). This demonstration is over twice as fast as the 10Hz video we show above...
    Posted to Other by Stephen Minne on Sat, Jun 11 2011
    Filed under: TappingMode, FastScan, Celgard
  • Celgard Fans: Fresh FastScan Video –or- Another High-Speed AFM benchmark sample?

    Nothing like a quality sample preparation (thanks Natalia!) and an awesome AFM to get great soft-sample high-speed images (thanks Shuiqing & Adam!). This new video shows height and phase of freshly prepared Celgard; the images are at ~20um/s (or 10Hz scan rate for 1um images): In the video, we also...
    Posted to SPM Digest by Stephen Minne on Fri, May 6 2011
  • Celgard imaged at ~20um/s with Bruker Dimesnion FastScan

    Nothing like a quality sample preparation (thanks Natalia!) and an awesome AFM to get great soft-sample high-speed images (thanks Shuiqing & Adam!). This new video shows height and phase of freshly prepared Celgard; the images are at ~20um/s or 10Hz scan rate for 1um images. In the video, we also...
    Posted to Webinars and Video by Stephen Minne on Fri, May 6 2011
    Filed under: TappingMode, FastScan, Celgard
  • Celgard Images: Magonov and Whangbo, VCH (1996)

    Excerpts of Figure 13.25 and 13.29 from Magonov and Whangbo,"Surface Analysis with STM and AFM," VCH (1996). See video: for FastScan images
    Posted to Publications by Stephen Minne on Fri, May 6 2011
    Filed under: TappingMode, FastScan, Celgard
Page 1 of 1 (20 items)
Copyright (c) 2011 Bruker Instruments