Vinnie, The latest V5 version is V5.31R1. Both V5.30R3sr3 and V5.31R1 run under XP Pro. Bruker AFM Service currently provides and supports RDSF computers with XP PRO using SP3 and latest XP Windows updates for V5. V5 is unqualified under Windows 7 and there is no plan to upgrade V5 for Windows 7 support. Please contact Service if they are experiencing
-
Sandeep, Here are the instructions on how to post a file: http://nanoscaleworld.bruker-axs.com/nanoscaleworld/forums/t/526.aspx Otherwise, you can email to me at steve.minne (at) bruker-nano.com. Version 8 SW does require MM8, but that can be upgraded from a MMV Steve
-
Sandeep, I checked with the team and we are not completely clear on what you describe. Give the following a try, if it is not what you need, could you send a screen shot of the problem? To bring up the NanoScope DOS debug window use “-console” as a command line argument when starting Z.exe. (Edit the shortcut to: z.exe –console). That
-
The Viton ring is p/n 30-600-0506 (production area stock location 021). Give Bruker Probes or TechSupport a call to order. Steve
-
Dimitry, There may be others, but here are a couple good options. http://gwyddion.net/ (free) or http://www.imagemet.com/ Good luck, Steve
-
UMEÅ UNIVERSITET Department of Medical Biochemistry and Biophysics PhD IN MEDICAL BIOPHYSICS UMEÅ UNIVERSITY, SWEDEN £27,800 - £32,800 pa A competitive Ph.D. position is open in the Department of Medical Biochemistry and Biophysics, Umeå University, Sweden to work on the project “Molecular and cellular mechanisms
-
OK. Keep us posted. It sounds like you are doing everything right, so this may be a service issue. If you will be out for 3 weeks you may want to consider contacting tech support, so the repair can be underway while you are gone. http://www.bruker-axs.com/nano_surfaces_support.html Best, Steve
-
Hi Jonas, We looked at your files and indeed the behavior is strange. We think there may be an equipment problem. Do you have an extra scanner? If so can you repeat the measurement with the different scanner, using a different probe, on a silicon sample? If you still have a problem, we can set up a TeamViewer session to take the next step. Thanks, Steve
-
Jay, Check out this training manual, I think it will answer a lot of your questions: MANUAL, TRAINING STANDARD VERSION-E (004-130-000).pdf I would also recommend having someone who knows the system spend a few hours with you to get you started. This will get you productive much faster. The TESPA should have a higher sum. The A stands for aluminium coating
-
This Notebook is intended to be used as an introduction by the first-time user of Veeco Instruments NanoScope Scanning Probe Microscopes (SPM). For further information, please consult the Command Reference Manual and/or the appropriate NanoScope manual. Specifically, this manual covers the following: • History and Definitions in SPMs: Page 3 •