The Nanoscale World

Search

  • Re: combine SECM with AFM

    Hi Teddy, Thank you for your suggestion. Arthur
    Posted to SPM Digest (Forum) by Arthur Tseng on Sun, Feb 14 2016
  • Re: combine SECM with AFM

    Hi Peter, Thanks for your help. I already try what you have suggested, but still have some questions. 1. I connect the current output signal from potentiostat to analog input 2 on backside of the controller and select the input 2 in software. The image scale always shows "voltage", but what I want is ampere in scale. How can I change the scale
    Posted to SPM Digest (Forum) by Arthur Tseng on Thu, Feb 4 2016
  • Re: combine SECM with AFM

    Hi Peter, Thanks for your comments. I still have some questions wanting to figure them out. Should I must have a bipotentiostat for conducting SECM? because now I have is a normal potentiostat (micro autolab). I roughly know the biopentiostat is connected to the tip (working electrode) and sample. I think we can set the sample ground by using the software
    Posted to SPM Digest (Forum) by Arthur Tseng on Mon, Feb 1 2016
  • Re: combine SECM with AFM

    Is there anyone can help me? Thank you very much.
    Posted to SPM Digest (Forum) by Arthur Tseng on Tue, Jan 26 2016
  • Re: ECAFM in liquid

    Dear Chunzeng Can I do ECAFM with the following AFM equipmnt? Veeco, Bioscope ; scanner - hybrid ; NanoScope IVa Controller ; Singal Access Module III Thank you very much.
    Posted to SPM Digest (Forum) by Arthur Tseng on Fri, Jan 22 2016
  • combine SECM with AFM

    Hello, everyone I would like to modify our AFM (Veeco, Bioscope ; scanner - hybrid) with NanoScope IVa Controller and Singal Access Module III (SAM) to enable SECM mapping (current mapping). I saw a paper. They mentioned that data signals from the potentiostat were fed into the Multimode software using a Bruker Signal Access Module. But the SAM is so
    Posted to SPM Digest (Forum) by Arthur Tseng on Thu, Jan 21 2016
  • setpoint below the minimum limit

    Dear all, I used a kind of tip to conduct AFM. But it always shows the error message - the engage setpoint has fallen below the minimum limit -when I try to land the tip. Is there any possible reason caused that problem? The technical data of tip is as the following. force constant : 2N/m ; resonant frequency : 25kHz Thank you for any response.
    Posted to SPM Digest (Forum) by Arthur Tseng on Wed, Sep 16 2015
  • Re: Potential difference in KPM measurement

    Hi Teddy, Thank you for your information. Best regards, Arthur
    Posted to SPM Digest (Forum) by Arthur Tseng on Sun, Jul 12 2015
  • Re: Potential difference in KPM measurement

    Hi, Ian Thank you for your advice. It's very clear to me. I will try it. Best regards, Arthur
    Posted to SPM Digest (Forum) by Arthur Tseng on Wed, Jul 8 2015
  • Potential difference in KPM measurement

    Hi All, I measured two different metal(Au & Pd) in KPM mode. The Pd is overlapping with Au. Basically, the work functions of Au and Pd are about 5.1eV and 5.22eV, respectively. I expect that the potential difference of these two metal measured by KPM is about 0.1V(=100mV), but the measured value is much less than that (only 10~20mV). Thank you for
    Posted to SPM Digest (Forum) by Arthur Tseng on Tue, Jul 7 2015