I can almost not immaging that reclueing it is a problem, but I would contact the service from Bruker, for me it looks like a bad made part, they (should) exchange it, but ....... i am not Bruker. If they not replace it I would try to reclue and try because in this case yoiu have to buy the part anyway.... Joop
-
Hello Jimmy, Can not realy see whats the problem on your airholder, made a picture of mine, hope you can find out your problem. Tried to get the picture here on the site, but looks like thats not working anymore. https://www.dropbox.com/s/ftx07gocq4tq6zx/IMG_6748.JPG?dl=0 Best regards, Joop
-
I have a dimension 3100 with Nanoscoop V and a catalyst also with the nanoscoop V. Would be helpful if you can explain how to get it out, tried it, but only got the Zsensor movement out, not the deflection. The one where we can get the signal is a dimesion 3100 with a naoscoop IV. But there we have the head connected (split cable) to a NI card, but
-
If have tried to read the deflection signal (in ramp mode) through one of the output BNC on the front panel of a Nanoscoop V. Tried different things but I don't think this is possible. Is there anybody who knows if it is possible and how to do it? I think it is possible with a Direct Access Module, but I don't have have one. I can do it on an
-
As far as I can see it, it has something to do with your sample, is it "very" rough? I think the first curve is not good because the start of the curve is with the tip on the surface and not away from the surface, it still gets the 2nN reletive trigger, then withdraws. Check it on a glas sample withe a normal tip if you get the same, don't
-
Try using version 1.4. I know it sounds stupid but version 1.5 and 1.6 are full of bugs and strange things especial in the force-curve part. For force curve manipullation I always use version 1.4. If you dont have it let me know I can sent you a dropbox link
-
another one....... did you check if there was not a protecting thin sheet over your callibration sample? Do you have the PFQNM manual ( PEAKFORCE QNM USERS GUIDE-C (004-1036-000) ) If not give me your mail adres, i can sent it
-
another one....... did you check if there was not a protecting thin sheet over your callibration sample?
-
The first thing that can help, probably your sc is to high for the polimers. according to the PFQNM manual it should be mesured with scan asist air witch is around 0.4 N/m
-
This movie is a good start at least to check if you are doing everything ok https://vimeo.com/user15273673/review/119890124/ec51c428e4