The Nanoscale World

Search

  • Re: What is CITS mode and how we can use it?

    Thank you for the reply... would it be possible for you to elaborate "quasi-CIST" method with version 8.x a little bit more? is there any reading material on this?
    Posted to SPM Digest (Forum) by Din on Wed, May 30 2012
  • What is CITS mode and how we can use it?

    Hello, We have a Nanoscope V multimode SPM (software:nanoscope 8.10). Since we do not have a multimode STM scan head, for scanning tunneling microscopy/spectroscopy studies we use a separate STM base and a scanner head and connect it to the controller box that operates the multimode SPM. Recently I read about the CITS mode (current imaging tunneling
    Posted to SPM Digest (Forum) by Din on Tue, May 29 2012
  • Re: Information on STS ramp

    Thank you Stephen for the information on posting images!! So here is the realtime plot: And here is the offline plot of the same data. I looked through the parameters and the 'plot invert' only inverts data but doesn't correct the X axis values...
    Posted to SPM Digest (Forum) by Din on Tue, Sep 13 2011
  • Re: Information on STS ramp

    Oh, It didn't show the images...I will email the figures to you Dinushi
    Posted to SPM Digest (Forum) by Din on Fri, Sep 9 2011
  • Re: Information on STS ramp

    Dear Chunzeng, Thank you so much for the information. I appreciate all the explanations and I guess now I can carefully look through, and adjust them to get better data. I will change parameters and soon send you few STS i(V) curves. I do have few more question... when I switch from STM imaging to STS Ramp, it doesn't show any curves at once. I
    Posted to SPM Digest (Forum) by Din on Fri, Sep 9 2011
  • Information on STS ramp

    Hello, We recently bought a Nanoscope V multimode SPM and we operate a separate STM base and a scanner head with the new controller box (software: nanoscope 8.10). Previously we operated the STM with Nanoscope III controller (software: nanoscope 5.12r4). With the new system, there are few things that I need to verify and I sincerely hope someone could
    Posted to SPM Digest (Forum) by Din on Tue, Sep 6 2011
  • Information on STS ramp (nanoscope V 8.10)

    Normal 0 false false false EN-US X-NONE X-NONE We recently bought a Nanoscope V multimode SPM and we operate a separate STM base and a scanner head with the new controller box (software: nanoscope 8.10). Previously we operated the STM with Nanoscope III controller (software: nanoscope 5.12r4). With the new system, there are few things that I need to
    Posted to SPM Digest (Forum) by Din on Fri, Sep 2 2011